Beispielbild

ChromCart HPLC column EC 50/2 Nucleodur 100-3 C8 ec lenght: 50 mm, ID: 2 mm pack of 1

Int. Ø

Length

Volume column

Spezifikationen

Modelle vergleichen
HS-Code #
90279000
Kohlenstoffgehalt
10,5 %
Eluent in der Säule
Acetonitril/Wasser
Endkappe
Ja
Hinein
2,0 mm
Länge
50 mm
Materialspalte
Edelstahl
Maximale Temperatur Widerstand
60 °C
Verfahren
Analytisch
Partikelgröße
3 µm
Partikeltyp
Vollständig porös

516.46€

Inkl. MwSt

Bald verfügbar

Produktbeschreibung

Octyl phases, 10.5 % C, particle size 3 µm.

Ähnliche Modelle vergleichen

ChromCart HPLC column EC 50/2 Nucleodur 100-3 C8 ec lenght: 50 mm, ID: 2 mm pack of 1

Manufacturer P/N

760063.20

Part Number

4.004 388

Manufacturer

Macherey-Nagel

Hinein

2,0 mm

EC HPLC column EC 250/4.6 NUCLEODUR 100-3 C8 ec length: 250 mm, ID: 4.6 mm pack of 1

Manufacturer P/N

760062.46

Part Number

4.004 387

Manufacturer

Macherey-Nagel

Hinein

4,6 mm

EC HPLC column EC 150/4.6 NUCLEODUR 100-3 C8 ec length: 150 mm, ID: 4.6 mm pack of 1

Manufacturer P/N

760061.46

Part Number

4.004 383

Manufacturer

Macherey-Nagel

Hinein

4,6 mm

EC HPLC column EC 250/4 NUCLEODUR 100-3 C8 ec length: 250 mm, ID: 4 mm pack of 1

Manufacturer P/N

760062.40

Part Number

4.004 386

Manufacturer

Macherey-Nagel

Hinein

4,0 mm

ChromCart HPLC column EC 50/4 Nucleodur 100-3 C8 ec lenght: 50 mm, ID: 4 mm pack of 1

Manufacturer P/N

760063.40

Part Number

4.004 390

Manufacturer

Macherey-Nagel

Hinein

4,0 mm

ChromCart HPLC column EC 50/4.6 Nucleodur 100-3 C8 ec lenght: 50 mm, ID: 4.6 mm pack of 1

Manufacturer P/N

760063.46

Part Number

4.004 391

Manufacturer

Macherey-Nagel

Hinein

4,6 mm

EC HPLC column EC 125/3 NUCLEODUR 100-3 C8 ec length: 125 mm, ID: 3 mm pack of 1

Manufacturer P/N

760060.30

Part Number

4.004 380

Manufacturer

Macherey-Nagel

Hinein

3,0 mm

EC HPLC column EC 125/4 NUCLEODUR 100-3 C8 ec length: 125 mm, ID: 4 mm pack of 1

Manufacturer P/N

760060.40

Part Number

4.004 381

Manufacturer

Macherey-Nagel

Hinein

4,0 mm

EC HPLC column EC 250/2 NUCLEODUR 100-3 C8 ec length: 250 mm, ID: 2 mm pack of 1

Manufacturer P/N

760062.20

Part Number

4.004 384

Manufacturer

Macherey-Nagel

Hinein

2,0 mm

ChromCart HPLC column EC 50/3 Nucleodur 100-3 C8 ec lenght: 50 mm, ID: 3 mm pack of 1

Manufacturer P/N

760063.30

Part Number

4.004 389

Manufacturer

Macherey-Nagel

Hinein

3,0 mm

EC HPLC column EC 125/2 NUCLEODUR 100-3 C8 ec length: 125 mm, ID: 2 mm pack of 1

Manufacturer P/N

760060.20

Part Number

4.004 379

Manufacturer

Macherey-Nagel

Hinein

2,0 mm

EC HPLC column EC 250/3 NUCLEODUR 100-3 C8 ec length: 250 mm, ID: 3 mm pack of 1

Manufacturer P/N

760062.30

Part Number

4.004 385

Manufacturer

Macherey-Nagel

Hinein

3,0 mm

EC HPLC column EC 125/4.6 NUCLEODUR 100-3 C8 ec length: 125 mm, ID: 4.6 mm pack of 1

Manufacturer P/N

760060.46

Part Number

4.004 382

Manufacturer

Macherey-Nagel

Hinein

4,6 mm

Einblicke

Erkunden
Was ist ein Rundkolben? Aufbau, Formen und Anwendung

8 Min. Lesezeit

Was ist ein Rundkolben? Aufbau, Formen und Anwendung

Ein Rundkolben ist ein kugelförmiges Laborgefäß, das zum Erhitzen, Mischen, Destillieren und Durchführen chemischer Reaktionen verwendet wird. Dieser Ratgeber erklärt die verschiedenen Formen, Materialien, Normschliffe, Anwendungen und wichtigen Sicherheitsaspekte.

Ganzer Artikel
Messkolben: Der Schlüssel zur präzisen Herstellung von Lösungen im Labor

2 Min. Lesezeit

Messkolben: Der Schlüssel zur präzisen Herstellung von Lösungen im Labor

Die Genauigkeit bei chemischen und biologischen Experimenten hängt von präzisen Messungen ab, und Messkolben gehören zu den wichtigsten Laborglasgeräten für die Herstellung präziser Lösungen. Diese Spezialkolben sind für die exakte Volumenmessung ausgelegt und daher für die analytische Chemie, pharmazeutische Untersuchungen und die Laborforschung unverzichtbar.

Ganzer Artikel